PROFIBUS DP Communication
8.6 DP slave MCP 310
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
259
Additional I/Os
The function: "Additional I/Os" transfers the data of all non-standard I/Os:
● Direct keys
● Customer keys: 6 signals (bit 0 to bit 6)
● Rotary switch
with the following distribution:
● Input data: 5 bytes
QGURWDU\
VZLWFK
VWURWDU\
VZLWFK
'LUHFWFRQWURONH\V
23
&XVWRPHU
NH\V
+LJK%\WH
/RZ%\WH
● Output data: 2 bytes
5HVHUYHG&XVWRPHU
DOZD\V/('V
/RZ%\WH
+LJK%\WH
8.6.4 Configure MCP 310 DP slave
The chapter describes the configuration of an MCP 310 DP slave with the help of the
configuration of a SIMATIC S7 project displayed in the following figure.
The configuration comprises the following modules:
● SIMATIC Station 300 with SINUMERIK 810D/840D and PLC 317-2DP
● SINUMERIK MCP with module: standard, handwheel, extended
The following steps must be performed within the framework of the S7 project to configure
the MCP 310 DP slave:
1. Insertion of the MCP 310 DP slave in the configuration
(see following figure: 1)
2. Setting the PROFIBUS address
3. Insertion of the corresponding modules in the MCP 310 DP slave as a function of the
desired functions.
(see following figure: 2)
4. Setting the I/O addresses of the individual slots