NC Commissioning with HMI Advanced
11.7 Digital and analog I/O devices
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
473
● T
M
Master time: Offset of the start time for NC position control
● GC
Global Control: Broadcast message for cyclic convergence of the equidistance between
DP master and DP slaves
● R
Computational time of position controller or signal module
● Dx
Useful data exchange between the DP master and DP slaves
● MSG
Acyclic services (e.g. DP/V1, pass token)
● RES
Reserve: "Active break" until the equidistant cycle has expired
● ①
Set the system variables, e.g. $A_OUT[8] in the part program or synchronized action
● ②
Transmit the output signal to the signal module via the PROFIBUS DP
● ③
Connect the signal to the output of the module.
11.7.6 Configuration example
In the following configuration example, the following digital input/outputs are available to the
NC:
ET 200
● 24 digital inputs
● 16 digital outputs
ADI4
● 8 digital inputs
● 16 digital outputs
Note
The following is to be taken into account:
• The I/O addresses of the modules are assigned automatically by "HW Config" (manual
adjustment is possible).
• Each I/O address is related to an input/output byte.