User data backup/Series commissioning
15.2 Creating a series commissioning file
Manual
546 Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
15.2.3 SinuCom NC
Starting
SinuCom NC can be started as follows to create a series startup file:
● SINUMERIK Desktop (see Chapter
"Service Desktop" (Page 135))
Windows taskbar: Start > Programs > SinuCom NC > SinuCom NC
● HMI Advanced
Operating area switchover > ETC key ">" SinuCom NC
Creating a new file
Creating a series startup file with SinuCom NC is subdivided into the following steps (see the
following screen):
1. Starting SinuCom NC
2. Selecting the storage location
3. Selecting the components to back up (archive content)
4. Continuing ("Next >")
6WRUDJHORFDWLRQ
'DWD6WRUDJH
)LOHV\VWHP
$UFKLYHFRQWHQW
1&
ZLWKFRPSHQVDWLRQGDWD
3/&
352),%86GULYHV
00&
1H[W!
&UHDWHDQDUFKLYH
Figure 15-2 Menu: Creating a series startup archive
5. The following data can be selected in the following menus, depending on the selected
components:
– NCK: Part programs
– MMC: MMC archive
6. Creating the series startup file ("Finish")