Alarm and message texts
12.4 Syntax for alarm text files
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
497
12.4 Syntax for alarm text files
Alarm numbers
The following alarm numbers are available for the cycle, compile cycle and PLC alarms:
Table 12-2 Alarm numbers for cycle, compile cycle and PLC alarms
Number range Description Effect Delete
60000-60999 Cycle alarms (Siemens) Display, interlocking NC start Reset
61000-61999 Display, NC start disable,
motion standstill
Reset
62000-62999 Display Cancel
63000-64999 Reserved
65000-65999 Cycle alarms (user) Display, interlocking NC start Reset
66000-66999 Display, NC start disable,
motion standstill
Reset
67000-67999 Display Cancel
68000-69000 Reserved
70000-79999 Compile cycle alarms
400000-499999 PLC alarms general
500000-599999 PLC alarms for channel
600000-699999 PLC alarms for axis and spindle
700000-799999 PLC alarms for users
800000-899999 PLC alarms for sequence
cascades/graphs
Format of the text file for cycle alarm texts
The structure of the text file for cycle and compile cycle alarms is as follows:
Table 12-3 Structure of text file for cycle alarm texts
Alarm number Display Help ID Text or alarm number
60100 1 0 "No D number %1 is programmed"
60101 1 0 60100
... ... ... ...
65202 0 1 "Axis %2 in channel %1 is still moving"
// Alarm text file for cycles in English
References:
/FB/ Function Manual - Basic Functions; P3 Basic PLC Program, Chapter "Lists"
Alarm number
List of alarm numbers