Axis and Spindle Test Run
13.1 Requirements
Manual
502 Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
13.1.2 Drives: SIMODRIVE
Relevant terminals
Applies to the following SIMODRIVE drives:
● SIMODRIVE 611 universal/universal E
● SIMODRIVE POSMO SI, CD/CA
The following terminals must be connected:
I/RF module
Terminal Description
63 Pulse enable
64 Drive enable
48 DC-link start
Drive Module
Terminal Description
663 Pulse enable
Signal TRUE: +24 V (e.g. from terminal 9)
References:
/FBU/ Function Manual SIMODRIVE 611 universal
/POS3/ User Manual - SIMODRIVE SI/CD/CA
13.1.3 NC/PLC interface signals
Relevant NC/PLC interface signals
The following NC/PLC interface signals must be set:
DB number Byte.Bit Value Description
31, ... 0 <> 0% Feedrate/spindle override
31, ... 1.3 FALSE Axis/spindle disable
31, ... 1.4 FALSE Follow-up mode
31, ... 1.5 TRUE Position measuring system 1
1)
31, ... 1.6 TRUE Position measuring system 2
1)
31, ... 1.7 TRUE Override active
31, ... 2.1 TRUE Controller enable
31, ... 2.2 FALSE Distance-to-go/Spindle reset
31, ... 4.3 FALSE Feed stop/spindle stop
31, ... 4.4 FALSE Traversing-key lock
31, ... 4.6
3)
Traversing key -
31, ... 4.7
3)
Traversing key +