EasyManua.ls Logo

Siemens SINUMERIK 840Di sl - Technical Data

Siemens SINUMERIK 840Di sl
632 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Hardware Descriptions
2.3 MCI board extension slot variation
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
63
TTL handwheels
Electrical data of the TTL handwheel interface:
Connected to the board electronics
Signals used:
MPGx_A
MPGx_B
M
NOTICE
The optional power supply of the handwheels (P5) is electronically protected with 2
A. The maximum continuous load is 1 A. Per handwheel 500 mA.
Measuring inputs
Electrical data of the measurement probe interface:
Isolated both from one another and from all other voltage areas (board electronics, digital
inputs/outputs and handwheels)
Signal delay active edge: 10 μs
Signal delay inactive edge: 100 μs
Note
The maximum cable length is 25 m for all functions.
2.3.4 Technical data
Table 2-7 Technical data for MCI board extension, slot version
Safety
Degree of protection IP 20
Safety class Safety class I, in accordance with VDE 0106 P1: 1982 (IEC 536)
Safety regulations EN61131-1
Certifications CE, UL, CSA
Electrical data
Maximum Standard
Power consumption without I/Os 500 mW 350 mW
Power consumption with I/Os 2.1 W 850 mW
both handwheels per handwheel
Max. current-carrying capacity of
the 5 V power supply
1 A 500 mA
Mechanical data
Dimensions Short PCI card
Weight 110g

Table of Contents