PROFIBUS DP Communication
8.11 DP slave diagnostic repeater for PROFIBUS DP
Manual
306 Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
Galvanic separation of the PG interface:
Galvanically or electrically isolating the PG interface prevents interference with the other
bus segments of the PROFIBUS DP if the PG connecting cable is inserted or removed,
even at high baud rates.
Monitoring functions of the clock-synchronous PROFIBUS
8.11.2 Area of application
A diagnostic repeater is required if one or more of the following requirements exist:
Cable diagnosis of PROFIBUS network during operation
Connection of more than 32 nodes on a PROFIBUS line
Implementation of branches
Electrical isolation of two segments
Ungrounded operation of bus segments
Visualization of bus topology with STEP 7 (Version 5.2 and higher)
8.11.3 Connection and commissioning
You will find a detailed description of how to connect and commission a diagnostic repeater
in:
References:
SIMATIC Manual: Diagnostic repeater for PROFIBUS DP
Drawing number: A5E00352937-01, 10/2004 Edition
Order number (MLFB): 6ES7972-0AB00-8AA0

Table of Contents

Other manuals for Siemens SINUMERIK 840Di sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840Di sl and is the answer not in the manual?

Siemens SINUMERIK 840Di sl Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 840Di sl
CategoryControl Unit
LanguageEnglish

Related product manuals