Drive Optimization with HMI Advanced
14.6 Trace function
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
527
,IWKHFXUVRULVSODFHGRQDOLVW
ER[SUHVVWKH,QVHUWNH\WR
RSHQWKHOLVWER[
7KHFXUVRULVFRQWUROOHG
XVLQJWKHDUURZNH\VRQ
WKHRSHUDWRUSDQHORUZLWK
WKHPRXVH
7RJJOHNH\
<RXFDQVFUROOGRZQE\
XVLQJWKHDUURZNH\V
<RXDFFHSWDYDOXH
XVLQJWKHLQSXWNH\
Figure 14-8 Cursor operation
14.6.3 Parameter assignment
Parameterization in the basic display
The following settings have to be made in the basic screen
● The axis/spindle to be measured
● The signal to be measured
● Measurement time
● Trigger time
● Trigger type
● Trigger threshold
Input field: Axis/spindle name
The cursor must be positioned on the Axis/Spindle name of the relevant trace. You can
select it with the softkeys Axis+ and Axis- or by accepting a value from the dropdown list.
Input field: Signal selection
The cursor must be positioned on the Signal selection list field of the relevant trace. Then
activate the desired items by selecting them from the list box.