Hardware Descriptions
2.3 MCI board extension slot variation
Manual
64 Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
Climatic environmental conditions
Heat dissipation Open-circuit-ventilated
operation Storage/transport
Temperature limits 5 ... 55°C -40 ... 70°C
Tested according to DIN IEC 68-2-1, DIN IEC 68-2-2
(DIN EN 60068-2-2), DIN IEC 68-2-14
Limits for relative humidity 5 ... .80% 5 ... .95%
Tested according to DIN IEC 68-2-30
Per minute Per hour
Rate of temperature change Max. 1 K Max. 10 K
Condensation Not permissible
Quality assurance to ISO 9001
Vibrational load during operation
Class 3M4
Frequency range 10 ... 58 Hz/58... 200 Hz
Const. excursion/
acceleration
0.075 mm / 1g
Tested as per
- module in PCU 50.3
DIN EN 60068-2-6
Shock load during operation
Acceleration 50 m/s
2
Duration of nominal shock 30 ms
Tested as per
- module in PCU 50.3
DIN EN 60068-2-6
Note
The specified safety regulations, certifications, degree of protection and safety class only
apply if the module is plugged into a SINUMERIK PCU 50.3.