Ethernet communication
7.5 MCP 483C IE
Manual
200 Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
Output image
The following information is to be found in the table for each output bit:
● 1. Row: Default designation
● 2. Row: LED number
Table 7-3 Assignment of the LED signals in the input image
Signals to machine control panel (keys)
Byte Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
Machine function Mode AB n+0
1000 INC
LED11
100 INC
LED09
10 INC
LED08
1 INC
LED06
JOG
LED01
TEACH
LED04
MDA
LED07
AUTO
LED10
Machine function AB n+1 Feed Start
LED50
Feed Stop
LED49
NC Start
LED16
NC Stop
LED15
REPOS
LED02
REF
LED03
var. INC
LED05
10000 INC
LED12
Axis selection AB n+2
R13
LED44
R1
LED32
R4
LED35
R7
LED38
R10
LED41
Single
Block
LED14
Spindle
Start
LED48
Spindle
Stop
LED47
Axis selection AB n+3
R3
LED34
R5
LED36
R12
LED43
R11
LED42
R9
LED40
R8
LED39
R6
LED37
R15
LED46
Freely assignable customer keys Axis
selection
AB n+4
T9
LED25
T10
LED26
T11
LED27
T12
LED28
T13
LED29
T14
LED30
T15
LED31
R2
LED33
Freely assignable customer keys AB n+5
T1
LED17
T2
LED18
T3
LED19
T4
LED20
T5
LED21
T6
LED22
T7
LED23
T8
LED24
AB n+6 - - - - - - RESET
LED13
(optional)
R14
LED45
(optional)
AB n+7 - - KT_OUT6 KT_OUT5 KT_OUT4 KT_OUT3 KT_OUT2 KT_OUT1
- Free signals
Note
We recommend setting free signals to 0 in the user program.