Ethernet communication
7.6 HT 8
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
221
Signals from HT 8
Byte Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
Ax6- Ax5- Ax4- Ax3- Ax2- Ax1-
EB n+4 {U16} {U15} {U14} {U13} {U12} {U11} {U10} {U9}
EB n+5 - {U8} {U7} {U6} {U5} (SBL) - -
EB n+6 Res. HT 6/8 SF2 SF1 SF4 SF3 START STOP
Feed override EB n+7 - - -
E D C B A
[xx] = Functions that can be initiated only via the touchscreen softkey
{Ux} = User softkeys of the CPF, display via "U" key; standard labeling: U1 - U16; User-specified Inscription possible via
language-based file: HT8_xx.INI, path: /Siemens/Sinumerik/<HMI>/mmc2/language/
with xx: GR = German, UK = English, SP = Spanish, IT = Italian, GR = Greek, CH = Chinese
Note
It is recommended that the original file in .../mmc2/language/ be left unchanged and the user-specific. file be stored in one
of the following directories: .../user/language, .../oem/language, or /addon/language.
(...) = Signals from the function keys (softkeys) of the CPF, display via the "U" key
- unassigned signals
Note
Unassigned signals are transferred from HT 8 with 0.
Output image
The address specification of the output image EB takes place in the FB 1 function module,
parameters: "MCPxOut", with x = 1 for the 1st MCP and x = 2 for the 2nd MCP.
Table 7-7 Assignment of the signals in the output image
Signals to HT 8
Byte Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
Function keys AB n + 0
REF TEACH AUTO MDA JOG QUIT RESET WCS/MCS
Function keys AB n + 1
- FCT15 FCT14 BigFct FCT12 FCT11 INC REPOS
Traversing keys + AB n + 2 - Axes 7 - n
selected
Ax6+ Ax5+ Ax4+ Ax3+ Ax2+ Ax1+
Traversing keys - AB n + 3 for WCS:
no machine
axes
-
Ax6- Ax5- Ax4- Ax3- Ax2- Ax1-
AB n + 4 - - - - - - - -
AB n + 5 - - - - - - - -
AB n + 6 Display
traversing
keys
- SF2 SF1 SF4 SF3 START STOP
AB n +7 - - - - - - - -
- unassigned signals
Note
We recommend setting unassigned signals explicitly to 0 in the user program.