PROFIBUS DP Communication
8.2 Requirements
Manual
236 Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
840Di sl Rack
The 840Di sl rack is a SIMATIC-300 station preconfigured for SINUMERIK 840Di sl. The
following version is available in the hardware catalog of HW Config:
SINUMERIK 840Di sl with PLC 317-2DP 2AJ10
Slot 2: SINUMERIK 840Di sl PLC
Default designation: PLC317-2DP 2AJ10
Slot X1: MPI/PROFIBUS interface (X102)
Default designation: MPI/DP
Slot X2: PROFIBUS interface (X101)
Default designation: DP
Slot 4: SINUMERIK 840Di sl NC
Default designation: NCK 840D sl
Slot 5: SINUMERIK CP for Industrial Ethernet TCP/IP
Default designation: CP 840D sl
Installation
The 840Di sl rack is part of the PLC Toolbox. When the PLC Toolbox is installed, it is
automatically installed in SIMATIC STEP 7.
Note
The PLC basic program must be installed on the computer on which SIMATIC STEP 7 is
installed. For installing the PLC basic program, please observe the appropriate notes in the
file:
< Installation path>\importantinfo.rtf
Once the PLC basic program has been successfully installed the 840Di sl rack can be
accessed in the hardware catalog of SIMATIC STEP 7, "HW Config":
"HW Config" hardware catalog:
Profile: Standard
SIMATIC 300 > SINUMERIK > 840Di sl > 840Di sl
SlaveOM
The SlaveOM (Slave Object Manager) for SINUMERIK 840Di sl enables the dialog-based S7
configuration of the following PROFIBUS drives:
SIMATIC S120
SIMODRIVE 611 universal or universal E
SIMODRIVE POSMO CD/CA
SIMODRIVE POSMO SI
SIMODRIVE POSMO A
ADI4 (Analog Drive Interface for 4 Axes)