PROFIBUS DP Communication
8.6 DP slave MCP 310
Manual
266 Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
Customized response
The following organization blocks can be added to the PLC user program to customize the
response to a DP slave MCP 310 failure:
OB 82: Diagnostic interrupt
OB 86: Rack failure
Please refer to the corresponding SIMATIC literature for details of linking organization blocks
and evaluating diagnostic data.
NOTICE
No alarm is initiated by the basic PLC program if there is a failure of an MCP connected via
PROFIBUS. The triggering of a corresponding alarm is the sole responsibility of the user
(machine manufacturer).