EasyManua.ls Logo

Siemens SINUMERIK 840Di sl - Page 273

Siemens SINUMERIK 840Di sl
632 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PROFIBUS DP Communication
8.7 DP slave MCP 483
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
273
VWGLJLW
OHIW/('%ORFN
QGGLJLW
FHQWHU/('%ORFN
UGGLJLW
ULJKW/('%ORFN
(QDEOHVRIWZDUHYHUVLRQGLVSOD\
SUHVVERWKNH\VVLPXOWDQHRXVO\
Figure 8-18 MCP software version display
Switch S3
The PROFIBUS address and the connection type are set via Switch S3 on the rear side of
the MCP:
Table 8-4 Switch S3: PROFIBUS address (1-7)
10
9
8
7 6 5 4 3 2 1 Meaning/value
on on - - - - - - - - Connection type: PROFIBUS
- - off - - - - - - - Reserved
PROFIBUS address
- - - off off off off off off off 0
- - - off off off off off off on 1
- - - on off off off off on off 2
- - - off off off off off on on 3
- - - : : : : : : : :
- - - on on on on on on off 126
- - - on on on on on on on 127
The switch position 10-8 are to be set according to the data in the table.
NOTICE
In the delivery condition, MPI is to be set as connection type (10-9: off, off).