30 Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
NOTICE
One of the following connection variants must be used for full back-up protection:
Variant 1: Connection 1) and 2)
Variant 2: Connection 3)
1)
2)
SIEMENS
/LQHLQIHHG
9$&+]
6,72332:(5
VWDQGDUG9$
6,72332:(5'&8690RGXOPLW
6,72332:(5$..802'8/
(7,2
IUHHZLULQJ
352),%86'3
0&,%RDUG
0&,%RDUG([WHQVLRQRSWLRQ
6,180(5,.'LVO
IUHHZLULQJ
86%&RQQHFWLRQ
Figure 1-2 Possible connections: USV
Configuration
The UPS functionality can be configured in two different ways:
When using SITOP POWER DC UPS MODULE 15 (see Section
"Uninterrupted Power
Supply UPS" (Page
87)) with a special software tool.
Download: http://www.siemens.de/sitop > Further topics: Download Software DC UPS 15
A
With Windows XP standard tools.
Start menu: Start > Settings > Control Panel > Power Options > Tab: UPS
Note
If the SINUMERIK user interface HMI Advanced (option) is installed on the PCU, the
application F:\mmc2\hmiexit.exe must be executed with the UPS software, before the
shutdown of the PCU.