11.2 Machine and setting data
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
361
Possible characters
Up to eight characters are possible in a password. We recommend that you restrict yourself
to the character set of the operator panel in selecting a password. Where a password
consists of less than eight characters, the additional characters are interpreted as blanks.
Default passwords
The following default passwords have been set for protection levels 1 to 3:
● Protection level 1: SUNRISE
● Protection level 2: EVENING
● Protection level 3: CUSTOMER
NOTICE
A system power-up with loading the default machine data (after "Delete NC data", e.g.
using 840Di Startup) will reset the passwords to the default values.
These passwords should be changed to ensure effective access protection.
Redefining protection levels
The protection levels of machine and/or setting data can be modified both with respect to
complete machine or setting data ranges and for single data.
Data areas
Table 11-3 Protection levels: Machine data
Number Name Name
MMC machine data ($MM_.... )
9200 USER_CLASS_READ_TOA Read tool offsets
9201 USER_CLASS_WRITE_TOA_GEO Write tool geometry
9202 USER_CLASS_WRITE_TOA_WEAR Write tool wear data
9203 USER_CLASS_WRITE_FINE Write Fine
9204 USER_CLASS_WRITE_TOA_SC Change additive tool offsets
9205 USER_CLASS_WRITE_TOA_EC Change tool setup offsets
9206 USER_CLASS_WRITE_TOA_SUPVIS Change tool monitoring limit values
9207 USER_CLASS_WRITE_TOA_ASSDNO Change D No. assigned to a tool edge
9208 USER_CLASS_WRITE_MAG_WGROUP change wear group magazine location/mag.
9209 USER_CLASS_WRITE_TOA_ADAPT Tool adapter data
9210 USER_CLASS_WRITE_ZOA Write settable zero offset
9213 USER_CLASS_OVERSTORE_HIGH Extended overstore
9214 USER_CLASS_WRITE_PRG_CONDIT Program control
9215 USER_CLASS_WRITE_SEA Write setting data
9218 USER_CLASS_SELECT_PROGRAM Program selection