NC Commissioning with HMI Advanced
11.4 Memory configuration
Manual
384 Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
Machine data
Table 11-13 Machine data required to configure the SRAM
Number Name Name/remarks
General ($MN_ ... )
18060 INFO_FREE_MEM_STATIC Display data of the free static memory
18080 MM_TOOL_MANAGEMENT_MASK Screen form for reserving memory for the tool management
18082 MM_NUM_TOOL Number of tools managed by NC
18084 MM_NUM_MAGAZINE Number of magazines managed by NC
18086 MM_NUM_MAGAZINE_LOCATION Number of magazine locations
18090 MM_NUM_CC_MAGAZINE_PARAM Compile cycles of tool management: Number of magazine data
18092 MM_NUM_CC_MAGLOC_PARAM Compile cycles of tool management: Number of magazine
location data
18094 MM_NUM_CC_TDA_PARAM Compile cycles of tool management: Number of TDA data
18096 MM_NUM_CC_TOA_PARAM Compile cycles of tool management: Number of TOA data
18098 MM_NUM_CC_MON_PARAM Compile cycles of tool management: Number of monitor data
18100 MM_NUM_CUTTING_EDGES_IN_TOA Number of tool offsets
18118 MM_NUM_GUD_MODULES Number of GUD modules
18120 MM_NUM_GUD_NAMES_NCK Number of global user variables
18130 MM_NUM_GUD_NAMES_CHAN Number of channel-specific user variables
18140 MM_NUM_GUD_NAMES_AXIS Number of axis-specific user variables
18150 MM_GUD_VALUES_MEM Memory reserved for global user variables
18160 MM_NUM_USER_MACROS Number of macros
18190 MM_NUM_PROTECT_AREA_NCK Number of protection areas
18230 MM_USER_MEM_BUFFERED. User memory in SRAM
18270 MM_NUM_SUBDIR_PER_DIR Number of subdirectories
18280 MM_NUM_FILES_PER_DIR Number of files per directory
18290 MM_FILE_HASH_TABLE_SIZE Hash table size for files in a directory
18300 MM_DIR_HASH_TABLE_SIZE Hash table size for subdirectories
18310 MM_NUM_DIR_IN_FILESYSTEM Number of directories in passive file system
18320 MM_NUM_FILES_IN_FILESYSTEM Number of files in passive file system
18330 MM_CHAR_LENGTH_OF_BLOCK Max. length of an NC block
18350 MM_USER_FILE_MEM_MINIMUM Minimum NC program memory
28050 MM_NUM_R_PARAM Number of channel-specific R parameters
28080 MM_NUM_USER_FRAMES Number of settable frames
28085 MM_LINK_TOA_UNIT Allocation of a TO unit to a channel
28200 MM_NUM_PROTECT_AREA_CHAN Number of modules for channel-specific protection zones
Axisspecific ($MA_ ... )
38000 MM_ENC_COMP_MAX_POINTS Number of intermediate points with interpolatory compensation