NC Commissioning with HMI Advanced
11.5 Axes and spindles
Manual
440 Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
Machine data
Table 11-38 Referencing: Machine data
Number Name Name
General ($MN_ ... )
11300 JOG_INC_MODE_LEVELTRIGGRD INC/REF in jog/continuous mode
Channelspecific ($MC_ ... )
20700 REFP_NC_START_LOCK NC-Start disable without reference point
Axisspecific ($MA_ ... )
30200 NUM_ENCS Number of encoders
30240 ENC_TYP Actual value encoder type
30242 ENC_IS_INDEPENDENT Encoder is independent
31122 BERO_DELAY_TIME_PLUS BERO delay time in plus direction
31123 BERO_DELAY_TIME_MINUS BERO delay time in minus direction
34000 REFP_CAM_IS_ACTIVE Axis with reference cam
34010 REFP_CAM_DIR_IS_MINUS Reference point approach in minus direction
34020 REFP_VELO_SEARCH_CAM Reference point approach velocity
34030 REFP_MAX_CAM_DIST Maximum distance to reference cam
34040 REFP_VELO_SEARCH_MARKER Reference point creep speed
34050 REFP_SEARCH_MARKER_REVERSE Direction reversal to reference cam
34060 REFP_MAX_MARKER_DIST Maximum distance to reference mark; Maximum distance to two
reference marks with distance-coded scales
34070 REFP_VELO_POS Reference point positioning velocity
34080 REFP_MOVE_DIST Reference point distance/destination point for distancecoded
system
34090 REFP_MOVE_DIST_CORR Reference point/absolute offset, distancecoded
34092 REFP_CAM_SHIFT Electronic reference cam shift for incremental measurement
systems with equidistant zero marks.
34100 REFP_SET_POS Reference point value
34102 REFP_SYNC_ENCS Actual value adjustment to the referencing measurement system
34110 REFP_CYCLE_NR Axis sequence for channel-specific Homing
34120 REFP_BERO_LOW_ACTIVE Polarity change of BERO
34200 ENC_REFP_MODE Referencing mode
34210 ENC_REFP_STATE Status of absolute encoder
34220 ENC_ABS_TURNS_MODULO Absolute encoder range for rotary encoders
34300 ENC_REFP_MARKER_DIST Reference marker distance with distancecoded scales
34310 ENC_MARKER_INC Interval between two reference marks with distancecoded scales
34320 ENC_INVERS Linear measuring system inverse to machine system
34330 REFP_STOP_AT_ABS_MARKER Distance-coded linear measuring system without destination
destination point
35150 SPIND_DES_VELO_TOL Spindle speed tolerance
36302 ENC_FREQ_LIMIT_LOW Encoder limit frequency resynchronization
36310 ENC_ZERO_MONITORING Zero mark monitoring
30250 ACT_POS_ABS Absolute encoder position at time of deactivation.