NC Commissioning with HMI Advanced
11.5 Axes and spindles
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
449
Machine data
Table 11-39 Speeds and setpoint adjustment for spindle: Machine data
Number Name Name
Axisspecific ($MA_ ... )
31050 DRIVE_AX_RATIO_DENOM Denominator load gearbox
31060 DRIVE_AX_RATIO_NUMERA Numerator load gearbox
32010 JOG_VELO_RAPID Rapid traverse in JOG mode
32020 JOG_VELO Axis velocity in JOG mode
35010 GEAR_STEP_CHANGE_ENABLE Gear stage change possible
35020 SPIND_DEFAULT_MODE Basic spindle setting
35030 SPIND_DEFAULT_ACT_MASK Activate initial spindle setting
35040 SPIND_ACTIVE_AFTER_RESET Spindle active after reset
35200 GEAR_STEP_SPEEDCTRL_ACCEL[n] Acceleration in speed control mode
35220 ACCEL_REDUCTION_SPEED_POINT Speed limit for reduced acceleration
35230 ACCEL_REDUCTION_FACTOR Reduced acceleration
35400 SPIND_OSCILL_DES_VELO Oscillation speed
35410 SPIND_OSCILL_ACCEL Oscillation acceleration
35430 SPIND_OSCILL_START_DIR Starting direction during oscillation
35440 SPIND_OSCILL_TIME_CW Oscillation time for M3 direction
35450 SPIND_OSCILL_TIME_CCW Oscillation time for M4 direction
Interface signals
Table 11-40 Speeds and setpoint adjustment for spindle: Interface signals
DB number Bit, byte Name
Axis-specific Signals from PLC to axis/spindle
31, ... 4.6 Traversing keys minus
31, ... 4.7 Traversing keys plus
31, ... 16.2-16.0 Actual gear step
31, ... 16.3 Gear changed
31, ... 16.6 No speed monitoring when changing the gear
31, ... 18.4 Oscillation via PLC
31, ... 18.5 Oscillation speed
Axis-specific Signals from axis/spindle to PLC
31, ... 82.2-82.0 Set gear step
31, ... 82.3 Change gear stage
31, ... 84.7 Active spindle control mode