EasyManua.ls Logo

Siemens SINUMERIK 840Di sl - Page 98

Siemens SINUMERIK 840Di sl
632 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Hardware Descriptions
2.12 PP72/48 I/O module
Manual
98 Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
33
H[WSRZHUVXSSO\
9VWDELOL]HG
9
9
;;;
3LQQXPEHU

'2&20[
5HOD\V
'ULYHUV
'ULYHUV
'ULYHUV
:
:
:
:




1
(M)
0
Figure 2-24 Terminal assignment for the digital outputs
Connection cable: The required connecting cables (ribbon cables) must be provided by
the user
.
Supply voltage:
To supply the digital outputs, an external 24V DC power supply must be connected to
DOCOMx (X111, X222, X333: Pin 47, 48, 49, 50).
The reference ground of the external power supply source must be connected to X111,
X222, X333: Pin 1 (M)
For further data, see Subsection
"Power Supply" (Page 100).
CAUTION
It is the user's responsibility to ensure that the max. current consumption per DOCOMx
pin (X111, X222, X333: Pins 47, 48, 49, 50) does not exceed 1 A. The power supply
(+24 V DC) for the digital outputs must therefore be connected to all 4 pins (X111, X222,
X333: Pin 47, 48, 49, 50) for each DOCOMx.
Electrical specification of the digital outputs:
Table 2-19 Electrical specification of the digital outputs
Digital outputs min. Standard Max. Nominal
Voltage at high signal level (U
H)
V
CC
- 3 V
1)
V
CC
24V
Output current I
OUT
- - 250mA -
Voltage at low signal level (U
L)
- - - Output open
Leakage current at low level - 50mA 400mA -
Signal delay time T
PHL
2)
- 0.5 ms - -

Table of Contents

Other manuals for Siemens SINUMERIK 840Di sl