ATTENTION
Install cutter
U01W
• A hard metal cutter is required. Press ENTER to continue.
5.10.3 ALARM MESSAGES
ALARM 1
Key not
properly
installed !
• Keyblanknotproperlyttedintheloader,ornotproperlyloadedontotheautomaticclamp.
ALARM 2
Movement axis
not completely
zeroed!
• The message indicates that there is a fault on the axis referred to (X, Y or B) due to:
- an obstacle impeding free movement of the axis to complete its run
- a fault on the limit switch (do the sensor TEST)
- a fault on the motor that moves the axis (do the motor TEST)
- break down of motor control on the electronic board (do the motor TEST)
ALARM 3
HIGH TEMPERATURE
Turn the
machine off !
• The electronic control board has exceeded the maximum permitted temperature. Check the cooling fan (see
Ch. 7.1 Trouble shooting).
ALARM 4
I/O POWER
Check fuse F4 !
• Indicates that the fuse has blown due to a short circuit in an inlet or outlet (Ch.7.8).
ALARM 5
DIGITAL OUTLET
Turn the
machine off !
• Indicates a short circuit in port P (IN/OUT) (see Ch. 7.1 Trouble shooting)
ALARM 6
CUTTER MOTOR
Check fuse F1 !
• Indicates that the fuse has probably blown (see Ch. 7.8).
Operating Manual UC199
Copyright Silca 2012
67