Table C-4. Visible only appliances (retrofit)
P/N Description Device type
4904-9174 Visible Only 24VDC 30CD Red VER Free Run or Sync
SmartSync visible only
Legacy housing
4904-9175 Visible Only 24VDC 110CD Red VER Free Run or Sync
4904-9176 Visible Only 24VDC 15CD Red VER Free Run or Sync
4904-9177 Visible Only 24VDC 15CD White VER Free Run or Sync
4904-9178 Visible Only 24VDC 15CD Red HORIZ Free Run or Sync
4904-9180 Visible Only 24VDC 30CD Red HORIZ Free Run or Sync
4904-9181 Visible Only 24VDC 110CD White VER Free Run or Sync
4904-9182 Visible Only 24VDC 110CD Red HOR Free Run or Sync Discontinued
4904-9183 Visible Only 24VDC 15CD Red CEIL Free Run or Sync
SmartSync visible only
Ceiling mount
4904-9184 Visible Only 24VDC 30CD Red CEIL Free Run or Sync
4904-9185 Visible Only 24VDC 110CD Red CEIL Free Run or Sync
4904-9345 Visible Only 24VDC 15CD White PLAIN Free Run or Sync
4904-9346 Visible Only 24VDC 30CD White PLAIN Free Run or Sync
4904-9168 Visible Only 15CD Red FREE-RUN TrueAlert Non-Addressable
Free-run visible only
4904-9169 Visible Only 75CD Red FREE-RUN TrueAlert Non-Addressable
4904-9170 Visible Only 110CD Red FREE-RUN TrueAlert Non-Addressable
4904-9171 Visible Only 15CD White FREE-RUN TrueAlert Non-Addressable
4904-9172 Visible Only 75CD White FREE-RUN TrueAlert Non-Addressable
4904-9173 Visible Only 110CD White FREE-RUN TrueAlert Non-Addressable
4904-9331 Visible Only 15CD Red SYNC TrueAlert Non-Addressable
Discontinued
4904-9332 Visible Only 75CD Red SYNC TrueAlert Non-Addressable
4904-9333 Visible Only 110CD Red SYNC TrueAlert Non-Addressable
4904-9342 Visible Only 15CD White SYNC TrueAlert Non-Addressable
4904-9343 Visible Only 75CD White SYNC TrueAlert Non-Addressable
4904-9344 Visible Only 110CD White SYNC TrueAlert Non-Addressable
4098-9772 Sensor Base with 520 Hz Sounder Free-run audible only
4098-9773 Co Sensor Base with 520 Hz Sounder
Table C-5. Miscellaneous
P/N Description
4090-9005 Suppression Release Peripheral (SRP)
4090-9006 Suppression Release Peripheral (SRP) w/ENCLOSURE
4905-9815 SMARTSYNC ADAPTER, TrueAlert Non-Addressable
4905-9938 SMARTSYNC CTL MODULE
Special app. NAC-compatible notification app. and acc., continued

Table of Contents

Other manuals for Simplex 4010ES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Simplex 4010ES and is the answer not in the manual?

Simplex 4010ES Specifications

General IconGeneral
Control Panel TypeAddressable Fire Alarm Control Panel
DisplayLCD
Operating Temperature32°F to 120°F (0°C to 49°C)
Power Supply120V AC or 240V AC
Zones10
Communication PortsRS-232, Ethernet
Signaling Line Circuits (SLCs)2
Notification Appliance Circuits (NACs)4
Max Notification AppliancesVaries based on NAC configuration and power supply
Communication OptionsCellular, Ethernet
Weight30 lbs
Humidity RangeUp to 93% non-condensing
CertificationsUL, FM, CSFM, MEA