viii
Table of Contents
Common earth fault ground indicator .......................................................................... A-2
Overview ............................................................................................................................. A-2
Step 1. Open CPU card properties dialog ........................................................................... A-2
Step 2. Program the LED .................................................................................................... A-3
Simultaneous alarm display .......................................................................................... A-4
Overview ............................................................................................................................. A-4
Creating annunciation zone lists ......................................................................................... A-4
Programming the address and mode for each LED ............................................................ A-5
Setting alarm verification timer to Canadian operation .............................................. A-7
Introduction ......................................................................................................................... A-7
Procedure ........................................................................................................................... A-7
Setting Alarm Reset/Inhibit Timer ................................................................................. A-8
Overview ............................................................................................................................. A-8
Enabling Alarm Reset/Inhibit Timer .................................................................................... A-8
Alarm Cutout Timer ........................................................................................................ A-9
Overview ............................................................................................................................. A-9
Enabling Alarm Cutout Timer .............................................................................................. A-9
Chapter B UL programming requirements ......................................................B-1
Introduction ......................................................................................................................... B-1
In this chapter ..................................................................................................................... B-1
Setting Alarm Verification to US operation .................................................................. B-2
Overview ............................................................................................................................. B-2
Procedure ........................................................................................................................... B-2
Alarm Cutout Timer ........................................................................................................ B-3
Overview ............................................................................................................................. B-3
Enabling Alarm Cutout Timer .............................................................................................. B-3
Non Steady Visual Evacuation system option ............................................................. B-4
Overview ............................................................................................................................. B-4
Chapter C Simplex special application NAC-compatible notification appliances and
accessories ........................................................................................................C-1
Chapter D Cooper Wheelock appliances compatible with 4010ES Wheelock protocol
for special applications .....................................................................................D-1
Overview .............................................................................................................................D-1
Synchronizing horn strobes ................................................................................................D-1
Synchronizing strobes .........................................................................................................D-2
Appliances with synchronizing strobes ...............................................................................D-3
Synchronizing horns ...........................................................................................................D-4
Coded audible appliances ...................................................................................................D-5
Non-synchronizing appliances ............................................................................................D-5

Table of Contents

Other manuals for Simplex 4010ES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Simplex 4010ES and is the answer not in the manual?

Simplex 4010ES Specifications

General IconGeneral
Control Panel TypeAddressable Fire Alarm Control Panel
DisplayLCD
Operating Temperature32°F to 120°F (0°C to 49°C)
Power Supply120V AC or 240V AC
Zones10
Communication PortsRS-232, Ethernet
Signaling Line Circuits (SLCs)2
Notification Appliance Circuits (NACs)4
Max Notification AppliancesVaries based on NAC configuration and power supply
Communication OptionsCellular, Ethernet
Weight30 lbs
Humidity RangeUp to 93% non-condensing
CertificationsUL, FM, CSFM, MEA
Network CapabilityYes