147
SJ12 E, SJ16 E, SJ20 E
241914ACA
Display Module Section 5 – Procedures
Name Unit of Measure Description
SERVICE
POSITION
Number
(1)
Service mode active.
DIAGNOSTIC
Number
(1)
Service mode active with diagnostic input B8 active.
DECK
EXTENSION L
Number
(1)
Deck extension limit active.
ANTI OVER
RISNO
Number
(1)
Status of the normally open anti over rise input.
ANTI OVER RISNC
Number
(1)
Status of the normally closed anti over rise input.
ANTI OVER
RISING
Number
(1)
Status of the anti over rise function.
TELEMATICS DIS
Number
(1)
Status of the telematics disable function.
RAMP CUTBACK
Number
(1)
Status of the speed cutback function.
MAX SPEED
TRACT
Hertz
(0.1 Hz)
Maximum ground speed given the present tilt of the machine
OUTDOOR MODE OFF/ON
status of the outdoor mode function:
OFF = indoor;
ON = outdoor
OVER HEIGHT
Number
(1)
status of the over height function:
0 = under height;
1 = over height;
2 = over height with over shot;
PULSE DOWN
STATE
Number
(1)
status of the pulse down function