148
SJ6826RT, SJ6832RT
213560ABA
Section 5 – Procedures Engine
12. Once the correct rpm is reached, apply a drop
Loctite 242 to the thread, and tighten the jam
nut.
Low idle
screw
Low idle
jam nut
Figure 03
5.3-5 Replacing the Air Cleaner Element
Kubota recommends replacing the air cleaner element
once a year. More frequent changes may be needed
in dusty environments.
IMPORTANT
The air cleaner uses a dry element. Never apply oil
to it.
1. Unlatch and remove the air cleaner cap. Use
a cloth to clean any dirt or dust from out of the
cap.
2. Remove the old air cleaner element by pulling it
straight out.
3. Install a new air cleaner element, pushing rmly
to seat it.
4. Reinstall and latch the air cleaner cap, ensuring
the TOP mark is facing up.
To order go to Discount-Equipment.com