177
SJ6826RT, SJ6832RT
213560ABA
Load Sensing System Section 5 – Procedures
Total Data:
This message is displayed at the end of each phase, to conrm the number of measurements recorded by the
GP102.
Caldate
This message is prompting for the date to be entered; it is stored to identify when the machine was calibrated.
The last calibrate date can be viewed in DIAGNOSTICS / LOG. Press LEFT and RIGHT to select the ashing digits.
Press UP and DOWN to change the ashing digits. Press ENTER when the entry is complete. IMPORTANT: The
date 00/00/00 is not allowed!
Finished
This message conrms that calibration is complete and successful.
5.5-9 Curved/Group codes chart
Model Number of Extension Decks Curve Code Group Code
SJ6832 RT 1 Manual extension deck 56 15
SJ6826 RT 1 Manual extension deck 57 15