Load Sensing System Section 5 – Procedures
5.5-2 Machine Level Calibration
Procedure
IMPORTANT
Each phase must be completed before the next
phase can be carried out. All phases must be
completed before the aerial platform can be
operated. Always follow the instructions of the
Calibration instrument.
1. Ensure aerial platform is parked on a rm and
level surface.
2. Elevate the scissors high enough to lay a level
across the base tubes. Ensure there is no debris
on the base and the level sits at. Do not elevate
aerial platform higher than the high speed/tilt
override limit switch.
3. Manually operate the outriggers and level the
machine in 4 places: left side, right side, front
and rear. All 4 outriggers must be rmly placed
and all 4 tires are off the ground.
4. Double check that the aerial platform is level at
all 4 points.
5. Connect the EZcal tool to the P1 connector on
the CONTROL MODULE.
6. The display will show Help: Press Enter.
Access Level Procedure
7. By using Left/Right buttons, select the Access
Level (3 ) from the menu and press the ENTER
button.
8. The display will show Access Level: Code
(0000).
9. By using the Up/Down buttons, enter the
Access Level Code (1 1 2 2) followed by
pressing the ENTER button.
10. The display will show Access Level 2. By using
Left/Right buttons, select the Setups from the
menu and press the ENTER button.
11. The display will show Setups: Change Defaults.
Select the Change Defaults from the menu and
press the ENTER button.
12. The display will show Defaults, 0 = Custom.
By using Up/Down buttons, select the Defaults:
Code Setting for your Model (For default code,
refer to 55-9 Curved/Group codes chart ) from
the menu.
13. Press ENTER and followed by ESCAPE.
Calibrate Level Procedure
14. The display will show Setups Change Defaults.
By using Left/Right buttons, select the Calibrate
Level from the menu and press the ENTER.
15. The display will show Calibrate Level: Yes:
Enter, No: ESC. Select the Yes from the menu
by press the ENTER button.
16. The display will show Calibrate Level: Tilt
0.0’ , 0.0’. Select the ESCAPE from the menu
once.
17. The display will show Setups Calibrate Level
Select the ESCAPE from the menu once again.
18. The Calibration procedure is complete, unplug
and remove the EZcal.
19. Close the hydraulic/electric cabinet.