Load Sensing System Section 5 – Procedures
5.5-8 Control Module Load Calibration - Code Messages & Denitions
During calibration the following failure message may appear:
Refer to 5.4-5 Hand Held (EZcal) Calibration / Diagnostic Tool Key Functions.
Code F01: Check HWFS
This message is given if the GP102 startup tests have not completed.
▪ Check HELP message for more information.
Code F02: Not Ground Mode
This message is given if the machine is not in ground mode (P2-2 must be high).
▪ Calibration can only be carried out in ground mode.
Code F03: Not Stopped
This message is given if any function switch is closed.
▪ Check DIAGNOSTICS / SWITCHES to see which function switch is closed.
Code F04: Tilted
This message is given if the machine is tilted.
▪ Calibration must be carried out with the machine level. If the machine is level, use the SETUPS / TILT
SETUPS to set the GP102 level.
Code F05: Bad Height
This message is given if the height sensor output (P4-3) is out of range at the start of calibration.
▪ The height sensor output must be 3.7V. Check DIAGNOSTICS / SENSORS to see the output. A reading of
0V or 5V is probably due to a wiring problem.
Code F06: Check Elev
This message is given if the elevation switch (P2-10) is closed at the start of calibration, when the operator has
conrmed the “PLATFORM DOWN?” question.
▪ If the platform is down, check the elevation switch wiring.
Code F08: Check Elev
This message is given if the elevation switch (P2-10) is closed at the end of calibration, when the platform
should be fully raised.
▪ This message would occur if the UP switch was accidentally opened near the start of the lift. If the
platform is fully raised, check the elevation switch wiring.
Code F09: Bad Height
This message is given if the height sensor output (P4-3) is out of range at the start of calibration.
▪ The height sensor output must be 3.7V. Check DIAGNOSTICS / SENSORS to see the output.
Code F10: Bad Height
This message is given if the height sensor output (P4-3) is out of range at the end of calibration.
▪ The height sensor output must be between 0.9V and 4.1V. Check DIAGNOSTICS / SENSORS to see the
output. A reading of 0V or 5V is probably due to a wiring problem.
Code F11: Not Up
This message occurs at the start of calibration if the operator selects a function other than UP.
▪ Select the UP function only.