169
SJ6826RT, SJ6832RT
213560ABA
Load Sensing System Section 5 – Procedures
32. Hold the lower switch and keep holding it until the platform is fully lowered.
33. When the system detects the lower switch closed, the display shows Calibrate Load: Lower Empty
34. After a delay, the system stops the platform lowering and takes height and pressure measurements.
The display shows MEASURING #xx. When the measurements have been taken, the platform resumes
lowering.
NOTE
The lowerin,stopping,measuring,lowering
process continues until the platform is fully
lowered
35. When the platform is fully lowered (and height 0% is displayed), release the lower switch.
36. The display shows briey TOTAL DATA: 04 to indicate the number of measurements taken.
37. The display shows Calibrate Load: Caldate: mm/dd/yy.
It is recommended that the current date be entered here to provide easy taking of the data of last
calibration.
The current date must be entered using the LEFT/RIGHT and UP/DOWN buttons
38. Press ENTER to complete date entry (the information is stored).
39. The display shows Calibrate Load option.
40. Press the ESC button to exit the Calibrate Load option.Remove the jumper wire and re-connect the black
wire #14 to the coil removed earlier.
41. Close the hydraulic/electric tray.
NOTE
Continuing partially complete load calibration
Once a calibration phase has been successfully completed, it is not required to do it again (unless of course a
change to the vehicle such as a replacement sensor requires that calibration be repeated). This is useful if the
calibration procedure is interrupted – the remaining phases can be completed at a later time.
If a calibration phase has been successfully completed, a REDO message is displayed:
REDO DYNAMIC: NO
REDO LOADED: NO
REDO EMPTY: NO
If the phase does not need to be repeated, just press ENTER to move on.
If the phase does need to be repeated, press UP or DOWN to change NO to YES then press ENTER.