Instruction Manual for AS380 Series Elevator Integrated Drive Controller
Chapter 6 Introduction to the supporting products
143
6.6.7.4 Electrical Specification
6.6.7.4.1 Switching Input
Table 6.20 The swiching input specification
Number of input points
8 (plug-in terminal)
Input form
Common anode, low level input is valid
Input voltage
Absolute conduction
≤ 6V
Absolute shutdown value
≥ 18V
Input current
Characteristic operating current
100mA
Maximum operating current
200mA
Isolated group (common port)
1
Delay
Standard
10ms
Input frequency
amplitude limiting
Standard
1KHz
Cable length
Standard
Shielded
400 m
Non-shielded
200 m
6.6.7.4.2 Communication Port
Table 6.21 The communication port specification
Connection type
WAGO terminal
Signal type
Differential voltage
Communication mode
CAN bus
Maximum communication delay
10ms
6.6.7.4 Definitions of Input and Output Interfaces
Table 6.22 The definitions of the JP2 and JP3 port
No.
Position
Port No.
Port definition
Corresponding LED
JP2
JP2.1
Void
D104
JP2.2
TXA4-
Communication signal negative port of
No. 4 elevator in group control system
JP2.3
TXA4+
Communication signal positive port of
No. 4 elevator in group control system
JP2.4
TXV4-
Communication power negative port of

Table of Contents