Shanghai STEP Electric Corporation
Chapter 7 Parameter Table of Integrated Drive Controller
164
No.
Name
Factory
Setup
Scope
Unit
Remarks
F29
Service floor 1 (Set up if 116
floors are secure)
65535
065535
×
F30
Service floor 2 (Set up if 1732
floors are secure)
65535
065535
×
F31
Service floor 3 (Set up if 3348
floors are secure)
65535
065535
×
F190
Service floor 4 (Set up if 4964
floors are secure)
65535
065535
×
F33
Auomatic operation interval for
test run
5
060
s
F34
Automatic operation times for test
run.
0
065535
F35
Firefighting switch input
definition and firefighting mode
selection
0
065535
×
Bit0: 0: ordinary firefighting, 1:
Schindler fire mode
Bit1: 0: fireman switch without
lift car board; 1: fireman switch
with lift car board
Bit2: 0: ordinary firefighting
signal display; 1: Shandong
firefighting signal display
Bit3: 0: Motherboard X15 input
for firefighting return; 1:
Motherboard X15 input for
fireman switch
F36
Band-type Brake switch detection
mode
0
02
×
F40
Weight data bias
48
0100
%
F41
Weighter study and parameter
setup command.
0
0121020
30405060
×
F43
Buzzing/flashing function
selection for attendant status call
3
065535
×
.
F44
Serial communication address
(255 for non-monitor)
255
0255
×
F49
Emergency leveling orientation
mode
0
02
F50
Front door opening permission 1
(opening setup value for 116
floors)
65535
065535
×
F51
Front door opening permission 2
(opening setup value for 1732
floors)
65535
065535
×
F52
Front door opening permission 3
(opening setup value for 3348
floors)
65535
065535
×
F191
Front door opening permission 4
(opening setup value for 4964
floors)
65535
065535
×
F53
Rear door opening permission 1
(opening setup value for 116
floors)
0
065535
×
F54
Rear door opening permission 2
(opening setup value for 1732
floors)
0
065535
×
F55
Rear door opening permission 3
(opening setup value for 3348
floors)
0
065535
×
F192
Rear door opening permission 4
(opening setup value for 4964
floors)
0
065535
×