Appendix B Para. Fault List Summary
260
F18
Fire floor
1
164
×
F20
Base station return delay
time
0
065535
s
0 represents not open;
other numbers
represents open and
delayed time.
F21
Leveling switch motion
delay distance (full-speed)
6
040
mm
F22
Single and Duplex return
to base station
1
164
×
F23
Group control mode
0
03
×
F25
Input type 1 (normal open
or close setup for X0
X15 input point)
819
065535
×
F26
Input type 2 (normal open
or close setup for X16
X25 input point)
2
065535
×
F27
Elevator car board input
type (normal open or close
setup for GX0 GX15
input point)
0
065535
×
F28
Car roof input type
(normal open or close
setup for HX0 HX15
input point)
327
065535
×
F29
Service floor 1 (Set up if
116 floors are secure)
65535
065535
×
F30
Service floor 2 (Set up if
1732 floors are secure)
65535
065535
×
F31
Service floor 3 (Set up if
3348 floors are secure)
65535
065535
×
F190
Service floor 4 (Set up if
4964 floors are secure)
65535
065535
×
F33
Auomatic operation
interval for test run
5
060
s
F34
Automatic operation times
for test run.
0
065535