Instruction Manual for AS380 Series Elevator Integrated Drive Controller
261
Appendix B Para. Fault List Summary
F35
Firefighting switch input
definition and firefighting
mode selection
0
065535
×
Bit0: 0: ordinary
firefighting, 1:
Schindler fire mode
Bit1: 0: fireman
switch without lift car
board; 1: fireman
switch with lift car
board
Bit2: 0: ordinary
firefighting signal
display; 1: Shandong
firefighting signal
display
Bit3: 0: Motherboard
X15 input for
firefighting return; 1:
Motherboard X15
input for fireman
switch
F36
Band-type Brake switch
detection mode
0
02
×
F40
Weight data bias
48
0100
%
F41
Weighter study and
parameter setup
command.
0
012
102030
4050
60
×
F43
Buzzing/flashing function
selection for attendant
status call
3
065535
×
.
F44
Serial communication
address (255 for
non-monitor)
255
0255
×
F49
Emergency leveling
orientation mode
0
02
F50
Front door opening
permission 1 (opening
setup value for 1 16
floors)
65535
065535
×
F51
Front door opening
permission 2 (opening
setup value for 17 32
floors)
65535
065535
×