Appendix B Para. Fault List Summary
262
F52
Front door opening
permission 3 (opening
setup value for 33 48
floors)
65535
065535
×
F191
Front door opening
permission 4 (opening
setup value for 49 64
floors)
65535
065535
×
F53
Rear door opening
permission 1 (opening
setup value for 1 16
floors)
0
065535
×
F54
Rear door opening
permission 2 (opening
setup value for 17 32
floors)
0
065535
×
F55
Rear door opening
permission 3 (opening
setup value for 33 48
floors)
0
065535
×
F192
Rear door opening
permission 4 (opening
setup value for 49 64
floors)
0
065535
×
F56
Up leveling adjustment (50
to refernece value)
50
0240
mm
F57
Down leveling adjustment
(50 to refernece value)
50
0240
mm
F59
Zero speed brake delay
0
010.00
0.01s
F61
Arrival distance by arrival
gong
1200
04000
mm
F62
Anti-slipping limit time
32
2045
s
F65
Base electrode lock mode
0
01
×
0: No base lock, 1:
output contactor off,
immediate lock
F66
With or whithout upper
and lower limt
0
0-1
0
no
1
yes
F67
With or whithout
entension board
0
0-1
0
no
1
yes
F70
Light load uplink gain
100
0-300
F71
Light load lowlink gain
100
0-300
F72
Heavy load uplink gain
100
0-300
F73
Heavy load lowlink gain
100
0-300