Instruction Manual for AS380 Series Elevator Integrated Drive Controller
263
Appendix B Para. Fault List Summary
F74
Light load height gain
512
0-1024
F75
Heavy load height gain
512
0-1024
F115
Overtime opening door
15
330
s
F116
Overtime closing door
15
330
s
F117
Opening time for forced
closing
60
01800
s
F118
Opening time for the
disabled
10
01800
s
F120
Car call number when
anti-nuisance function
activates.
0
030
×
F121
Activate forced closing
function (0 represents not
activate)
0
01
×
F122
Signal delay release time
in Inspection.
0.3
010.0
s
F123
Call categories
0
03
x
F124
Define the function of
mainboard X16 input point
0
02
×
F128
Control of front and rear
doors
0
01
×
0: separate control of
front and back doors;
1: joint control of
front and back doors
F129
Activate the functions of
re-leveling and/or
pre-opening
0
03
×
F130
Maintain the
opening/closing torque
0
07
×
Bit0: 1: door
maintaining open
Bit1: 1: door
maintaining closed
Bit2: 1: door
maintaining closed
during operation
F131
Time section floor
blockade floor set
0
0-65535
F132
Time section floor
blockade beginning time
set
0
0-65535