Appendix B Para. Fault List Summary
264
F133
Time section floor
blockade closure time set
0
0-65535
F137
Service floor 1 (Floor 1~
16) when NS-SW function
is set.
65535
065535
×
F138
Service floor 2 (Floor 17~
32) when NS-SW function
is set.
65535
065535
×
F139
Service floor 3 (Floor 33~
48) when NS-SW function
is set.
65535
065535
×
F199
Service floor 4 (Floor 49~
64) when NS-SW function
is set.
65535
065535
×
F141
Time of delay release of
the main contactor (after
enabled)
0.50
0.5010.00
s
F145
Bus voltage gain
100
80120
F146
Position error distance
180
1801000
mm
F147
Protection of contact
detection
0
01
F152
Lighting delay (fans turned
off automatically, delay
lighting)
180
065535
S
0: do not turn off the
lights
F153
high-voltage input
detection with or without
hall door lock
1
01
×
0: No
1: Yes
F156
With or without lock relay
contact detection
1
01
×
0: No
1: Yes
F160
Whether the manual
removal of error
instruction activated
1
01
×
0: No
1: Yes
F161
The function of floor
blocking for a time slot
0
065535
×
Bit0: 1: block
instruction
Bit1: 1: block upward
call
Bit2: 1: block
downward call