Instruction Manual for AS380 Series Elevator Integrated Drive Controller
Chapter 3 Product function
3.Fireman Service
The fireman switch is set on in case of fire, the elevator will immediately clear out all instruction
& call and return to firefighting base station. Then system switches to fireman service mode.
4 The auxiliary car operating Panel
The auxiliary car operating panel is available for installation when the main car operating panel is
installed. Passengers can use it to register instruction and operate the doors.
5 operating panel for the rear door
Rear door operating panel is recommended when elevator has both front and rear door. Passenger
can use the rear door operating panel to register instruction and operate the doors.
6 operating panel for the disable
Operating panel for the disabled is available for the disabled to operate the elevators.
7 group control operation
Use group control controller to coordinate landing calls of elevators in the bank. In this way the
running efficiency of elevator can be improved. And function such as peak service and distribution
waiting state are provided. The group control system can control up to 8 units
8 communities (building) monitoring
Control system link to the PCs in monitoring room through CAN communication line. Working
staff can monitor the elevator position, running direction and fault condition and etc.
9 earthquake response function
Activate the earthquake function. if earthquake occur, the earthquake inspection device activated.
A contact signal from the device will be transferred to the control system. The control system will
instruct the running elevator to park at nearest floor and open the doors for passenger evacuation
as well as stop the elevator then.
10 car arrival gong
The Up/Down arrival gong installed at the top, bottom of the car will ring as the elevator
decelerate and level, alarming the passenger in car and hall that the elevator is leveling and about
to arrive.
11 arrival lamp at landing
Activate the function. The up/down arrival lamp installed at the hall of each floor will inform
passengers the upcoming arrival of the elevator.
12 arrival gong at landing
Activate the function. The up/down arrival gong at hall of each floor will inform passengers the
upcoming arrival of the elevator.
13 independent control of front and rear door
Passenger can make independent control of the front and rear door according to their own needs.
14 VIP priority service
A special service for the VIP passengers, the function enables the VIP passenger to arrival the
destination floor at fastest speed.
15 Emergency leveling when blackout
The building blackout causes the running elevator fail to reach the door zone and entrapment
occurs as the consequence. Under the above circumstance does the blackout emergency leveling
device activated. The elevator will be pushed at the low speed to the nearest door zone for
passenger evacuation.
16 service floor change-over by the switch control