Instruction Manual for AS380 Series Elevator Integrated Drive Controller
the up and down button to set the value. press the enter button to confirm, in which 1 mean
parking allowed, 0 mean parking prohibited.
Login authorization is required for the parking floor allowed modification, Once modify parameter
and press the enter button in non login stat, login menu will pop up.
15 instruction registration
Use up and down button to select the floor needed to register the instruction, press the enter button,
to register the instruction.
16 self-study instruction
The above picture will display once enter the menu.
Self-study instruction
Press the enter button when need to do the hoist way study, the figure in the lowest order start to
flash, press the up button , figure 0 change to 1. Press the enter button again to confirm, as the
above fig. the elevator start to do the hoist way self-study. If the value is set to 2, asynchronous
motor parameter self-study will start.
Login authorization is required for the self-study instruction modification, Once modify parameter
and press the enter button in non-login stat, login menu will pop up.
17 the front door opening allowed
Door open allowed enable or not
Floor
Front door
The above picture mean: shield 1 floor front door open allowed. Fd is the abbreviation of Front