STOBER 12 | Diagnostics
05/2019 | ID 442790.01
145
12.2.11 Event 40: Invalid data
The drive controller is interrupted:
§ The power unit is disabled and axis movement is no longer controlled by the drive controller
§ The brakes are no longer controlled by the drive controller and engage in the event of an inactive release override
(F06)
Number Cause Check and action
1: Fault
–
8: Wrong/illegal serial number
Invalid data in the internal memory
of the drive controller or option
module
Replace the drive controller or option module;
fault cannot be acknowledged
32: Electronic nameplate No data available in the electronic
nameplate
Deactivate the evaluation of the nameplate or
replace the motor (B04); fault cannot be
acknowledged
33: Electronic motor-type limit Invalid data in the electronic
nameplate
Deactivate the evaluation of the nameplate or
replace the motor (B04); fault cannot be
acknowledged
48: reverse documentation Defective memory in the SD card
or internal memory of the drive
controller
Replace the SD card or drive controller; fault
cannot be acknowledged
Tab. 157: Event 40 – Causes and actions

Table of Contents

Other manuals for Stober SC6A062

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Stober SC6A062 and is the answer not in the manual?

Stober SC6A062 Specifications

General IconGeneral
BrandStober
ModelSC6A062
CategoryController
LanguageEnglish

Related product manuals