Chapter 3 Server Diagnostics 3-53
FIGURE 3-12 SunVTS Test Selection Panel
6. (Optional) Select the tests you want to run.
Certain tests are enabled by default, and you can choose to accept these.
Alternatively, you can enable and disable individual tests or blocks of tests by
clicking the checkbox next to the test name or test category name. Tests are enabled
when checked, and disabled when not checked.
TABLE 3-12 lists tests that are especially useful to run on this server.
TABLE 3-12 Useful SunVTS Tests to Run on This Server
SunVTS Tests FRUs Exercised by Tests
cmttest, cputest, fputest,
iutest, l1dcachetest, dtlbtest,
and l2sramtest—indirectly: mptest,
and systest
DIMMS, CPU motherboard
disktest Disks, cables, disk backplane
cddvdtest CD/DVD device, cable, motherboard
nettest, netlbtest Network interface, network cable, CPU
motherboard
pmemtest, vmemtest, ramtest DIMMs, motherboard
serialtest I/O (serial port interface)
usbkbtest, disktest USB devices, cable, CPU motherboard (USB
controller)
hsclbtest Motherboard, system controller
(Host to system controller interface)

Table of Contents