Chapter 5 Replacing Cold-Swappable FRUs 5-17
If the fault was detected by the host and the fault information persists, the output
will be similar to the following example:
If the showfaults command does not report a fault with a UUID, then you do
not need to proceed with the following steps because the fault is cleared.
11. Run the clearfault command.
12. Switch to the system console.
13. Issue the fmadm repair command with the UUID.
Use the same UUID that you used with the clearfault command.
5.2.5 Removing the System Controller Card
Caution The system controller card can be hot. To avoid injury, handle it carefully.
1. Perform the procedures described in Section 5.1, “Common Procedures for Parts
Replacement” on page 5-1.
2. Locate the system controller card.
See Appendix A for an illustration of the servers FRUs that shows the system
controller card.
3. Push down on the ejector levers on each side of the system controller until the
card is released from the socket.
sc> showfaults -v
ID Time FRU Fault
0 SEP 09 11:09:26 MB/CMP0/CH0/R0/D0 Host detected fault, MSGID:
SUN4U-8000-2S UUID: 7ee0e46b-ea64-6565-e684-e996963f7b86
sc> clearfault 7ee0e46b-ea64-6565-e684-e996963f7b86
sc> console
# fmadm repair 7ee0e46b-ea64-6565-e684-e996963f7b86

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sun Microsystems Sun Fire T2000 and is the answer not in the manual?

Sun Microsystems Sun Fire T2000 Specifications

General IconGeneral
BrandSun Microsystems
ModelSun Fire T2000
CategoryServer
LanguageEnglish

Related product manuals