5-16 Sun Fire T2000 Server Service Manual July 2007
c. Switch to the system console to view POST output.
Watch the POST output for possible fault messages. The following output is a
sign that POST did not detect any faults:
Note Depending on the configuration of ALOM CMT POST variables and
whether POST detected faults or not, the system might boot, or the system might
remain at the ok prompt. If the system is at the ok prompt, type boot.
d. Return the virtual keyswitch to normal mode.
e. Issue the Solaris OS fmadm faulty command.
No memory or DIMM faults should be displayed.
If faults are reported, refer to the diagnostics flowchart in
FIGURE 3-1 for an approach
to diagnose the fault.
9. Gain access to the ALOM CMT sc> prompt.
10. Run the showfaults command.
sc> console
.
.
.
0:0>POST Passed all devices.
0:0>
0:0>DEMON: (Diagnostics Engineering MONitor)
0:0>Select one of the following functions
0:0>POST:Return to OBP.
0:0>INFO:
0:0>POST Passed all devices.
0:0>Master set ACK for vbsc runpost command and spin...
sc> setkeyswitch normal
# fmadm faulty

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sun Microsystems Sun Fire T2000 and is the answer not in the manual?

Sun Microsystems Sun Fire T2000 Specifications

General IconGeneral
BrandSun Microsystems
ModelSun Fire T2000
CategoryServer
LanguageEnglish

Related product manuals