Chapter 5 Replacing Cold-Swappable FRUs 5-15
6. Gain access to the ALOM CMT sc> prompt.
Refer to the Sun Fire T2000 Advanced Lights Out Management (ALOM) Guide for
instructions.
7. Run the showfaults -v command to determine how to clear the fault.
The method you use to clear a fault depends on how the fault is identified by the
showfaults command.
Examples:
If the fault is a host-detected fault (displays a UUID), continue to Step 8. For
example:
If the fault resulted in the FRU being disabled, such as the following,
Then run the enablecomponent command to enable the FRU:
8. Perform the following steps to verify the repair:
a. Set the virtual keyswitch to diag so that POST will run in Service mode.
b. Issue the poweron command.
sc> showfaults -v
ID Time FRU Fault
0 SEP 09 11:09:26 MB/CMP0/CH0/R0/D0 Host detected fault,
MSGID:
SUN4V-8000-DX UUID: 7ee0e46b-ea64-6565-e684-e996963f7b86
sc> showfaults -v
ID Time FRU Fault
1 OCT 13 12:47:27 MB/CMP0/CH0/R0/D0 MB/CMP0/CH0/R0/D0
deemed faulty and disabled
sc> enablecomponent MB/CMP0/CH0/R0/D0
sc> setkeyswitch diag
sc> poweron

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sun Microsystems Sun Fire T2000 and is the answer not in the manual?

Sun Microsystems Sun Fire T2000 Specifications

General IconGeneral
BrandSun Microsystems
ModelSun Fire T2000
CategoryServer
LanguageEnglish

Related product manuals