Page #152 background imageLoading...
Page #152 background image
2-100 SPARC Enterprise Mx000 Servers XSCF User’s Guide • August 2009
Caution – IMPORTANT - If the XSB associated with the specified LSB has been
configured in the domain configuration, the information that is set for the LSB
cannot be changed. Also, if the specified domain is running, the value of
configuration policy cannot be changed. To change the value, first turn off power to
the domain.
TABLE 2-23 lists the XSB status information. This information can be displayed by the
showboards(8) command.
TABLE 2-23 XSB Status Information
Item Explanation
XSB number XSB number.
DID Domain ID.
LSB LSB number that is used for domain.
assignment
(Assignment)
Status of pre-arranged registration in a domain
unavailable:
• XSB not yet mounted or assigned.
• XSB not yet configured.
available: ..... XSB in the system board pool state.
assigned: ..... XSB assigned to the domain.
power
(Pwr)
Indicates the XSB power status.
n: ..... XSB power off state
y: ..... XSB power on state
connectivity
(Conn)
Indicates the state of a hardware connection to a domain.
n: ..... System board pool state
The XSB has been deleted from the domain by hardware. (This includes a domain
shutdown.)
y: ..... XSB connected by hardware to the domain.
(The XSB is active in the domain or ready to be added to the Solaris OS.)
configuration
(Conf)
Status of a logical connection to a domain.
n: ..... Not added to the domain (Solaris OS).
y: ..... Active and added to the domain (Solaris OS).
test
(Test)
Indicates the diagnosis status. (Note)
Unmount: ..... XSB not yet mounted or defined.
Unknown: ..... Diagnosis not yet performed.
Testing: ..... Diagnosis in progress.
Passed: ..... Diagnosis completed normally.
Failed: ..... A diagnosis error was detected and XSB continuous operation is not
possible.

Table of Contents

Other manuals for Sun Microsystems Sun SPARC Enterprise M4000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sun Microsystems Sun SPARC Enterprise M4000 and is the answer not in the manual?

Sun Microsystems Sun SPARC Enterprise M4000 Specifications

General IconGeneral
BrandSun Microsystems
ModelSun SPARC Enterprise M4000
CategoryServer
LanguageEnglish

Related product manuals