1-20 SPARC Enterprise Mx000 Servers XSCF User’s Guide • August 2009
1.3.2 NTP Configuration and Time Synchronization
The system uses the XSCF Unit clock for the system standard time.
The domains in the server synchronize their times based on the XSCF Unit clock
when the domains are started. The XSCF Unit clock can be adjusted to the exact time
through a network connection to an external NTP server. In that way, the XSCF Unit
becomes the NTP server and an NTP client.
Only domains may specify XSCF as an NTP server.
Note – Alternatively, the domains can synchronize their times through a connection
to an external NTP server. However, there is a possibility that time differences exist
between the XSCF and the domain. If you connect the domain to an external NTP,
connect the high rank NTP server that supplies the time of the same accuracy as the
domain as for XSCF.
For details about NTP server setting, see Chapter 2.
TABLE 1-5 outlines XSCF and domain time synchronization methods.
1.3.3 The CD-RW/DVD-RW Drive Unit and Tape Drive
Unit
In the M3000 server, one domain monopolizes the DVD drive unit. In the
M4000/M5000 servers, the domain that uses a minimum XSB number of number 0
of the MotherBoard Unit (MBU#0) can use the CD-RW/DVD-RW drive unit and
tape drive unit (hereafter collectively called DVD drive/tape drive unit).
TABLE 1-5 XSCF Unit and Domain Time Synchronization
Client Primary NTP Server Time Synchronization Method
Domain XSCF Unit The domain time is adjusted to the XSCF Unit clock time.
XSCF Unit operates as the NTP server.
External NTP server The domain time is adjusted to the standard time of the external NTP
server.
XSCF No connection The XSCF Unit time is the time in initial system settings or the time
set by the setdate(8) command. For details on the setdate(8)
command, see the XSCF Reference Manual.
External NTP server The XSCF Unit time is adjusted to the standard time of the external
NTP server.

Table of Contents

Other manuals for Sun Microsystems Sun SPARC Enterprise M4000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sun Microsystems Sun SPARC Enterprise M4000 and is the answer not in the manual?

Sun Microsystems Sun SPARC Enterprise M4000 Specifications

General IconGeneral
BrandSun Microsystems
ModelSun SPARC Enterprise M4000
CategoryServer
LanguageEnglish

Related product manuals