2-128 SPARC Enterprise Mx000 Servers XSCF User’s Guide • August 2009
Note – The display for domain ethernet address (mac address) by the
showdomainmode(8) command is supported only on
M3000/M4000/M5000/M8000/M9000 servers that run certain versions of XCP
firmware (beginning with XCP 1082).
The Status of the Mode Switch on Solaris OS
When you execute the prtdiag(1M) command on Solaris OS, either "LOCK" or
"UNLOCK" is displayed in the output as the status of the mode switch of the
operator panel. The output varies depending on the combination of the value of the
secure variable, which is set on each domain by using the setdomainmode(8)
command and the key position of the mode switch on the operator panel.
TABLE 2-29 shows the status of the mode switch displayed in the prtdiag (1M)
command output which depends on the value of secure variable and the keyposition
of the mode switch on the operator panel.
For details of the setdomainmode(8) command, see the XSCF Reference Manual.
For details of the prtdiag(1M) command, see the Solaris OS documentation.
SPARC64 VI and SPARC64 VII Processors and CPU Operational Modes
Note – This section applies only to M4000/M5000/M8000/M9000 servers that run
or will run SPARC64â„¢ VII processors. On the M3000 server, only SPARC64 VII
processors are mounted and Solaris OS operates in SPARC64 VII enhanced mode.
The M4000/M5000/M8000/M9000 servers support system boards that contain
SPARC64â„¢ VI processors, SPARC64 VII processors, or a mix of the two processor
types.
TABLE 2-29 Value of Secure Variable and Status of Mode Switch
Value of secure
variable set by
setdomainmode(8) Key position of mode swich
Status of mode switch in the
prtdig(1M) output
on Service UNLOCK
off UNLOCK
on Locked LOCK
off UNLOCK

Table of Contents

Other manuals for Sun Microsystems Sun SPARC Enterprise M4000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sun Microsystems Sun SPARC Enterprise M4000 and is the answer not in the manual?

Sun Microsystems Sun SPARC Enterprise M4000 Specifications

General IconGeneral
BrandSun Microsystems
ModelSun SPARC Enterprise M4000
CategoryServer
LanguageEnglish

Related product manuals