EasyManuals Logo

Sun Microsystems Sun SPARC Enterprise M4000 User Manual

Sun Microsystems Sun SPARC Enterprise M4000
398 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #235 background imageLoading...
Page #235 background image
Chapter 4 Operation of the Server 4-15
2. Use the poweron(8) command to turn on power to the specified domain.
4.4.4 Domain Power Off
â–  Command operation
1. Use the showdomainstatus(8) command to check the power status of all
domains.
<Example 1> Turn on power to the specified domain.
XSCF> poweron -d 0
DomainIDs to power on:00
Continue? [y|n] :y
00 :Powering on
*Note*
This command only issues the instruction to power-on.
The result of the instruction can be checked by the
"showlogs power".
<Example 2> Cancel domain power on in progress.
XSCF> poweron -d 0
DomainIDs to power on:00
Continue? [y|n] :n
XSCF>
XSCF> showdomainstatus -a
DID Domain Status
00 Running
01 Running
02 Running
03 Powered Off

Table of Contents