4-12 SPARC Enterprise Mx000 Servers XSCF User’s Guide • August 2009
â–  showpowerupdelay
â–  setshutdowndelay
â–  showshutdowndelay
â–  setdualpowerfeed
â–  showdualpowerfeed
With the power operations, the following can be performed:
â–  System power on
â–  System power off
â–  Domain power on
â–  Domain power off
â–  Sending a Domain Panic Request (Solaris OS dump request)
â–  Domain reset
â–  Sending break signal to a domain
â–  Air-conditioning wait time administration
â–  Warm-up time administration
â–  Dual power feed
4.4.1 System Power On
â–  Command operation
1. Use the showdomainstatus(8) command to check the power status of the
system.
2. Use the poweron(8) command to turn on power to all domains.
XSCF> showdomainstatus -a
DID Domain Status
00 Running
01 Powered Off
02 Powered Off
03 Powered Off