1-16 SPARC Enterprise Mx000 Servers XSCF User’s Guide • August 2009
The following connections in the XSCF Unit connection configuration shown in
FIGURE 1-4 are described below:
â– Serial port connection
â– XSCF-LAN Ethernet connection
Serial Port Connection
The serial port enables workstations, PCs, and ASCII terminals to connect to the
XSCF through the serial (RS-232C) port. The user can use the XSCF Shell and access
the domain console through the XSCF Shell.
XSCF-LAN Ethernet Connection
XSCF-LAN Ethernet enables workstations and PCs to connect to the XSCF through
the XSCF-LAN port. The following can be used with XSCF-LAN Ethernet:
â– XSCF Shell via a SSH or telnet connection
â– XSCF Web from a web browser running on the terminal
â– Domain console access
â– Mail reports
â– SNMP notification
For details on these XSCF functions, see the following chapters:
â– Settings for each function: Chapter 2
â– Shell terminal and console connections: Chapter 3
â– XSCF Shell: Chapter 5
â– XSCF mail functions: Chapter 6
â– XSCF SNMP Agent functions: Chapter 7
â– XSCF Web: Chapter 9
1.3.1 Examples of LAN Connection Operations
The XSCF Unit has two 10/100 Mbps XSCF-LAN two ports. TABLE 1-2 to TABLE 1-4
outlines three XSCF-LAN operation examples.