Chapter 2 Setting Up XSCF 2-135
Specifying the CPU Operational Mode
Note – In the M3000 server, CPU operational mode cannot be configured.
â–  Command operation
1. Power off the domain.
2. Use the showdomainmode(8) command to specify the CPU operational mode.
3. Use the setdomainmode(8) command to set the CPU operational mode.
4. Use the showdomainmode(8) command to confirm that the CPU Mode is
compatible.
Note – Restart the domain to apply the settings to the domain. You may set the
initial diagnostic level, enable or disable the host watchdog function, break signal,
automatic boot, and CPU operational mode.
XSCF> showdomainmode -d 0
Host-ID :0f010f10
Diagnostic Level :max
Secure Mode :on
Autoboot :on
CPU Mode :auto
<Example> Specify SPARC64 VI compatible mode for CPU operational mode of domain
ID 0.
XSCF> setdomainmode -d 0 -m cpumode=compatible
Diagnostic Level :max -> -
Secure Mode :on -> -
Autoboot :on -> -
CPU Mode :auto -> compatible
The specified modes will be changed.
Continue? [y|n]:y
configured.
Diagnostic Level :max
Secure Mode :on (host watchdog: available Break-signal:non-receive)
Autoboot :on (autoboot:on)
CPU Mode :compatible

Table of Contents

Other manuals for Sun Microsystems Sun SPARC Enterprise M4000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sun Microsystems Sun SPARC Enterprise M4000 and is the answer not in the manual?

Sun Microsystems Sun SPARC Enterprise M4000 Specifications

General IconGeneral
BrandSun Microsystems
ModelSun SPARC Enterprise M4000
CategoryServer
LanguageEnglish

Related product manuals